233 research outputs found

    Nano-Dielectric Resonator Antenna Reflectarray/Transmittarray for Terahertz Applications

    Get PDF
    Nanoantennas have introduced wide bandwidth for fast data communications. The material properties of good conducting metals introduce plasmonic behavior at Terahertz frequencies. The material property of good conducting metals using Drude Lorentz model has been investigated. The radiation characteristics of nano-dielectric resonator antenna (NDRA) reflectarray at 633 nm have been investigated. A parametric study for the nano DRA unit cell dimensions and material has been introduced. A NDR with silver ground plane have been designed and analyzed. A nano-transmitarray unit-cell has been introduced for the analysis. A comparison between the radiation characteristics of 17×17 and 21×21 NDRA transmitarray has been given. A compromise between the nano-transmitarray size, maximum gain, and operating bandwidth is applied to Terahertz applications. The finite integral technique is used to carry a full wave analysis to design a NDRA reflectarray and a NDRA transmitarray

    Single/Dual-Polarized Infrared Rectenna for Solar Energy Harvesting

    Get PDF
    Single and dual linearly-polarized receiving mode nanoantennas are designed for solar energy harvesting at 28.3 THz. The infrared rectennas are used to harvest the solar energy and converting it to electrical energy.  The proposed infrared rectenna is a thin dipole made of gold and printed on a silicon dioxide substrate. Different shapes of the dipole arms have been investigated for maximum collected energy. The two poles of the dipole have been determined in a rectangular, circular and rhombus shapes. The rectenna dipole is used to concentrate the electromagnetic energy into a small localized area at the inner tips of the gap between the dipole arms. The dimensions of the different dipole shapes are optimized for maximum near electric field intensity at a frequency of 28.3 THz. A Metal Insulator Metal (MIM) diode is incorporated with the nanoantenna dipole to rectify the received energy. The receiving efficiency of the solar energy collector with integrated MIM diode has been investigated. A dual-polarized, four arms, rhombus shaped nanoantenna dipole for solar energy harvesting has been designed and optimized for 28.3 THz applications

    Radiation Characteristics Enhancement of Dielectric Resonator Antenna Using Solid/Discrete Dielectric Lenses

    Get PDF
    The radiation characteristics of the dielectric resonator antennas (DRA) is enhanced using different types of solid and discrete dielectric lenses. One of these approaches is by loading the DRA with planar superstrate, spherical lens, or by discrete lens (transmitarray). The dimensions and dielectric constant of each lens are optimized to maximize the gain of the DRA. A comparison between the radiations characteristics of the DRA loaded with different lenses are introduced. The design of the dielectric transmitarray depends on optimizing the heights of the dielectric material of the unit cell. The optimized transmitarray achieves 7 dBi extra gain over the single DRA with preserving the circular polarization. The proposed antenna is suitable for various applications that need high gain and focused antenna beam

    Dielectric Resonator Antenna Mounted on Cylindrical Ground Plane for Handheld RFID Reader at 5.8 GHz

    Get PDF
    Dielectric resonator antenna (DRA) mounted on cylindrical ground plane is investigated for handheld RFID reader applications at 5.8 GHz. The simplicity of the structure makes it practical in terms of cost, space, and ease of fabrication. The radiation characteristics of the antenna in free space and in the presence of a proposed compact reader device model and human hand are calculated. The antenna is circularly polarized and exhibits peak gain of 7.62 dB at 5.8 GHz with high front to back ratio of 15.5 dB. Using the same reader device model, a sequentially feeding 2×2 DRA array mounted on the same cylindrical ground plane is used for RFID reader antenna at 5.8 GHz. The array introduces high gain of 9.36 dB at 5.8 GHz with high front to back ratio of 10.48 dB. The 2×2 DRA array elements exhibit circular polarization over a frequency band of 1.1 GHz. The axial ratio is 1.1 dB at 5.8 GHz. The proposed reader model is simple and has a small size compared with that in the case of planar ground plane. The results are calculated using the finite element method (FEM) and compared with that calculated using the finite integral technique (FIT)

    Factors associated with quality of life of outpatients with breast cancer and gynecologic cancers and their family caregivers: a controlled study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Quality of life (QOL) issues are of interest in cancer because effective methods of treatment and detection have led to an increase in the number of long-term survivors. The objectives of the study were: to assess the subjective QOL of stable Sudanese women cancer outpatients and their family caregivers, using the WHO 26-item QOL Instrument; compare with matched general population groups, as well as diabetic and psychiatric patient groups; examine patient-caregiver concordance in ratings; and assess the variables associated with their QOL, with a view to identifying factors that can enhance quality of care.</p> <p>Methods</p> <p>Responses of oncology outpatients with breast cancer (117), cervical cancer (46) and ovarian cancer (18) (aged 44.6, SD 11.5) were compared with those of their family caregivers and matched general population groups. Data were analyzed by univariate and multivariate statistics.</p> <p>Results</p> <p>The cancer groups had similar QOL domain scores, which were significantly lower than those of their caregivers, but higher than the control group as well as those of psychiatric and diabetic patients studied previously. Patients who were married, with higher education, better employment, and with longer duration of illness had higher QOL. Patients on radiotherapy and their caregivers had higher QOL scores. Correlations between patient's ratings and caregiver impression of patient's QOL were high. Caregiver impression was a significant predictor of patient's and caregiver's QOL. Other predictors for the patient were: currently feeling sick and duration of illness; for the caregiver: feeling sick, relationship to patient, and age.</p> <p>Conclusion</p> <p>Cancer patients in stable condition and with psychosocial support can hope to enjoy good QOL with treatment. The findings constitute an evidence base for the country's cancer care program, to boost national health education about prognosis in cancer. Families living with women cancer patients are vulnerable and need support if the patient is recently diagnosed, less educated, single, not formally employed; and the caregiver is female, parent, younger, less educated, unemployed and feels sick. Clinicians need to invest in the education and support of family caregivers. The patient-caregiver dyad should be regarded as a unit for treatment in cancer care.</p

    Is Microsporidial keratitis an emerging cause of stromal keratitis? – a case series study

    Get PDF
    BACKGROUND: Microsporidial keratitis is a rare cause of stromal keratitis. We present a series of five cases of microsporidial keratitis from a single centre in southern India with microbiologic and histopathologic features. CASE PRESENTATION: Patient charts of five cases of microsporidial stromal keratitis diagnosed between January 2002 and June 2004 were reviewed retrospectively for clinical data, microbiologic and histopathologic data. The presence of microsporidia was confirmed by special stains on corneal scrapings and/or corneal tissues, and electron microscopy. All patients were immunocompetent with a preceding history of trauma in three. Four patients presented with unilateral, small, persisting deep stromal infiltrates, of uncertain etiology, in the cornea, which were not responding to conventional antimicrobial treatment and required penetrating keratoplasty in three. Fifth case was unsuspected and underwent keratoplasty for post-traumatic scar. Three of five cases were diagnosed on corneal scrapings, prior to keratoplasty, while two were diagnosed only on histology. The microsporidia appeared as oval well defined bodies with dense staining at one pole. None of the patients showed recurrence following keratoplasty. CONCLUSION: Microsporidia, though rare, should be suspected in chronic culture-negative stromal keratitis. Organisms could lie dormant without associated inflammation

    Electrocardiographic features of immune checkpoint inhibitor associated myocarditis

    Get PDF
    Background Myocarditis is a highly morbid complication of immune checkpoint inhibitor (ICI) use that remains inadequately characterized. The QRS duration and the QTc interval are standardized electrocardiographic measures that are prolonged in other cardiac conditions; however, there are no data on their utility in ICI myocarditis. Methods From an international registry, ECG parameters were compared between 140 myocarditis cases and 179 controls across multiple time points (pre-ICI, on ICI prior to myocarditis, and at the time of myocarditis). The association between ECG values and major adverse cardiac events (MACE) was also tested. Results Both the QRS duration and QTc interval were similar between cases and controls prior to myocarditis. When compared with controls on an ICI (93±19 ms) or to baseline prior to myocarditis (97±19 ms), the QRS duration prolonged with myocarditis (110±22 ms, p<0.001 and p=0.009, respectively). In contrast, the QTc interval at the time of myocarditis (435±39 ms) was not increased compared with pre-myocarditis baseline (422±27 ms, p=0.42). A prolonged QRS duration conferred an increased risk of subsequent MACE (HR 3.28, 95% CI 1.98 to 5.62, p<0.001). After adjustment, each 10 ms increase in the QRS duration conferred a 1.3-fold increase in the odds of MACE (95% CI 1.07 to 1.61, p=0.011). Conversely, there was no association between the QTc interval and MACE among men (HR 1.33, 95% CI 0.70 to 2.53, p=0.38) or women (HR 1.48, 95% CI 0.61 to 3.58, p=0.39). Conclusions The QRS duration is increased in ICI myocarditis and is associated with increased MACE risk. Use of this widely available ECG parameter may aid in ICI myocarditis diagnosis and risk-stratification

    Austro-Asiatic Tribes of Northeast India Provide Hitherto Missing Genetic Link between South and Southeast Asia

    Get PDF
    Northeast India, the only region which currently forms a land bridge between the Indian subcontinent and Southeast Asia, has been proposed as an important corridor for the initial peopling of East Asia. Given that the Austro-Asiatic linguistic family is considered to be the oldest and spoken by certain tribes in India, Northeast India and entire Southeast Asia, we expect that populations of this family from Northeast India should provide the signatures of genetic link between Indian and Southeast Asian populations. In order to test this hypothesis, we analyzed mtDNA and Y-Chromosome SNP and STR data of the eight groups of the Austro-Asiatic Khasi from Northeast India and the neighboring Garo and compared with that of other relevant Asian populations. The results suggest that the Austro-Asiatic Khasi tribes of Northeast India represent a genetic continuity between the populations of South and Southeast Asia, thereby advocating that northeast India could have been a major corridor for the movement of populations from India to East/Southeast Asia
    corecore